Determination of the span distance at the installation location:
DIN 1055 specifies extensive calculation methods for the maximum pressure loads and suction
loads.
By inputting relevant parameters for the location at the following link http://www.sen.eu/de/Produkte/
Montagesysteme/lastermittlung.htm, you also have the possibility of determining the max. forces
arising. Compare these values with the tables shown below and thus determine the maximum per-
mitted span distance.
rafter distance/ horizontal distance of the roof hooks
1652
m m
1409
m m
1318
m m
1129
m m
rafter distance/ horizontal distance of the roof hooks
1000mm
pressure
suction
1652
m m
2,26 KN/m² -0,97 KN/m² 1 ,63 KN/m² -0,83 KN/m² 1 ,23 KN/m² -0,72 KN/m² 0,98 KN/m² -0,64 KN/m² 0,79 KN/m²
1409
m m
2,64 KN/m²
-1 ,1 3 KN/m²
1318
m m
2,83 KN/m²
-1 ,1 9 KN/m² 2,04 KN/m²
1129
m m
3,30 KN/m²
-1 ,41 KN/m² 2,38 KN/m² -1 ,20 KN/m² 1 ,80 KN/m² -1 ,05 KN/m² 1 ,43 KN/m² -0,93 KN/m²
The length of the cantilever arm should be at least 0.2 times and no more than 0.4 times the
span distance calculated!
Higher span distances and cantilever arm lengths differing from these are possible in special circum-
stances. Do not hesitate to contact us by telephone if you have any questions.
Reliable distributed load when using SOL– 50 roof hooks incl. base plate with pantiled roofs.
Attachment to the rafters.
600mm
700mm
pressure
suction
pressure
5,40 KN/m² -1 ,55 KN/m² 4,36 KN/m² -1 ,34 KN/m² 3,40 KN/m²
5,40 KN/m²
-1 ,81 KN/m² 5,1 2 KN/m² -1 ,57 KN/m² 3,98 KN/m² -1 ,38 KN/m² 3,21 KN/m²
5,40 KN/m²
1 ,92 KN/m² 5,40 KN/m² -1 ,66 KN/m² 4,26 KN/m² -1 ,47 KN/m² 3,43 KN/m²
5,1 7 KN/m² -2,26 KN/m² 5,40 KN/m² -1 ,96 KN/m² 4,97 KN/m² -1 ,73 KN/m² 4,01 KN/m²
1200mm
1400mm
pressure
suction
pressure
1 ,91 KN/m² -0,96 KN/m² 1 ,44 KN/m² -0,84 KN/m²
-1 ,01 KN/m² 1 ,54 KN/m² -0,88 KN/m² 1 ,23 KN/m² -0,78 KN/m² 0,99 KN/m²

Notes on statics

800mm
suction
pressure
suction
-1 ,1 9 KN/m² 2,74 KN/m²
1600mm
suction
pressure
suction
1 ,1 5 KN/m² -0,74 KN/m² 0,93 KN/m²
900mm
pressure
suction
-1 ,07 KN/m²
-1 ,24 KN/m²
-1 ,31 KN/m²
-1 ,55 KN/m²
1800mm
pressure
suction
-0,58 KN/m²
-0,67 KN/m²
-0,71 KN/m²
1 ,1 6 KN/m²
-0,84 KN/m²