Instructions
● Connecting the tone generator.
In terminated working cables:
Connect one test lead to a terminated wire and the
other test lead to earth or equipment ground.(See
figure 2)
In unterminated or non-working cables:
Connect one test lead to an unterminated wire and the
other test lead to another unterminated wire.
● Depress the round on/off spring-loaded button on the
amplifier probe. The volume control switch can be
adjusted to suit the environment. Volume can be
increased to overcome noise, or decreased to
reduce interference.
● Touch the tip of the amplifier probe to the insulation of
each suspect conductor.
● Reception of tone will be loudest on the subject wire.
● An audio jack is provided for headset.
Maintenance
The amplifier probe is maintenance free except for
battery replacement. Remove the screw from the
battery compartment, replace the 9V battery and
reassemble.
Warranty limited solely to repair or replacement; no
warranty of merchantability, fitness for a particular
purpose or consequential damages.
-
-
2