afx light FOG COLOR RGB Manuel D'utilisation page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connection of Signal Cable
You can use the 3-pin XLR cable to connect the output socket of the master and the input socket of the slave unit.
Connect the DIGITAL OUT socket of the master and the IN socket of the slave unit, then, connect the OUT socket to
the IN socket of the next light. Ordinal to connect all units as below:
1
2
3
I N
O U T
I N
O U T
I N
O U T
The connection between the output of master unit and the input of slave unit must be carried out by the 3-pin XLR
cable which is provided by the manufacturer. Connect the signal cable from the DMX output of the controller to the
input of the first master unit, then connect the DMX input of slave unit from the DMX output of the master unit, etc,
until you have connected all slaves. Insert the last connector to the input of the final light. (Note: the core diameter of
every cable should be 0.5mm at least, double core screened cable should be used).The signal connection must be
done via the supplied 3-pin XLR cable. Note: Make sure that the internal wires of the 3 pins XLR cable don't touch
each other or the connector.
A DMX signal terminator is recommended on the output of the last unit of the chain. A DMX terminator is a XLR
connector with a 120Ω resistor between pin 2 and pin 3 of the XLR connector
© Copyright LOTRONIC 2016
FOG COLOR RGB
Page 5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

15-1754

Table des Matières