3. Specifications
Specifications
Switching output
Number
■
Function
■
Adjustment
■
Temperature error
■
Accuracy
■
Max. switching current
■
Display of switch status
■
Response time
■
Hysteresis
■
Permissible temperature ranges
Ambient
■
Storage
■
Compensated
■
Temperature error
CE-mark
Ingress protection
Shock resistance
Vibration resistance
Electrical safety
Short-circuit resistance
■
Reverse polarity protection
■
Weight
For further specifications see WIKA data sheet AC 80.09, PE 87.20 and the order documentation.
WIKA operating instructions attachable indicator, models A-AS-1, WUR-1
Models A-AS-1, WUR-1
Individually adjustable via external control keys
2 x NPN open-collector (with bayonet connector: 1 x NPN
open-collector)
Galvanically-isolated switching outputs for 4 ... 20 mA
Normally open, normally closed
Freely-adjustable in the range 1 ... 99 % of span
< 0.1 % of span/10 K
≤ 0.5 % of span ±1 digit
300 mA
LED
< 15 ms
0.5 % (fixed)
-30 ... +85 °C
-30 ... +85 °C
-20 ... +80 °C
< 0.1 % of span/10 K
EMC directive 2004/108/EC, EN 61326 emission
(group 1, class B) and interference immunity (industrial
application)
IP 65 to IEC 60529
100 g to IEC 60068-2-27 (mechanical shock)
5 g at 10 ... 2,000 Hz to IEC 60068-2-6 (vibration at
resonance)
Sig
to 0V (short-term)
+
U
to 0V (short-term)
B+
50 g
GB