6. Commissioning, operation
Instrument connection (output)
Use the LED attachable indicator with shielded cable, and, if the lines are longer than
30 m or leave the building, earth the shield at least at one end of the cable.
Output
Circular connector M12 x 1; 5-pin
1
2
3
4
5
Cable outlet
red
black
yellow
brown
orange
Bayonet connector; 4-pin
A
B
C
D
WIKA operating instructions attachable indicator, models A-AS-1, WUR-1
2-wire
Current version
Power supply U
, Sig
B+
Switching output, out1
Power supply 0V, Sig -
Switching output ground
(potential-free)
Switching output, out2
Power supply U
, Sig
B+
Power supply 0V, Sig -
Switching output ground
(potential-free)
Switching output, out1
Switching output, out2
Power supply U
, Sig +
B+
Switching output ground
(potential-free)
Switching output, out1
Power supply 0V, Sig -
3-wire
Voltage version
Power supply U
+
Switching output, out1
Power supply 0V
Switching output ground, Sig -
Signal Sig
Switching output, out2
Power supply U
+
Power supply 0V
Switching output ground, Sig -
Signal Sig
Switching output, out1
Switching output, out2
Power supply U
Signal Sig
Switching output, out1
Power supply 0V
Switching output ground, Sig -
B+
+
B+
+
B+
+