Technical features / function
Technical features / function
- Switched functions and jumper positions for the four outputs L1 to L4:
Jumper position (FUNC.)
None (all pins open)
None (all pins open)
None (all pins open)
None (all pins open)
Top (centre pin to top pin)
Top (centre pin to top pin)
Top (centre pin to top pin)
Bottom (centre pin to bottom
Bottom (centre pin to bottom
Bottom (centre pin to bottom
pin)
- Select the desired function for each output L1 to L4, referring to the table above,
before switching the SXM on.
- When the SXM is switched on, all switched functions are always disabled, i.e. OFF.
- The switching contact connects (ON) or disconnects (OFF) the terminals (L1 to L4)
of the selected function to (-).
- If the control for the channel to which the SXM is connected (RX) is moved as in the
table below, the switched functions for L1 to L4 are activated or disabled.
Channel movement
- (negative) less than about 0.75 seconds
- (negative) more than about 0.75 seconds
+ (positive) less than about 0.75 seconds
+ (positive) more than about 0.75 seconds
- To minimise the risk of the unit switching on or off accidentally, a further switching
process cannot take place until the control for that channel is moved back in the
direction of neutral by a significant amount.
Receiver
connection
L1 L2 L3 L4
Function
On / Off (memory)
Momentary switch On / Off
Flashing light On / Off (memory) L1 and L2 at 1 Hz
RX
-
SXM
FUNC.
-
Battery
+
Switched function
L1
L2
L3
L4
(-)
Load
L1
(-)
L2
Load
L3
(-)
Load
L4
(-)
Load
6
Note
For L1 to L4
For L2 and L4 only