MONSUN
– Wireless rain gauge
Rainfall quantity of the last hour (1H), update every 10 minutes
Rainfall quantity of the last 24 hours (24H), update every hour
Rainfall quantity of the last rain
4.1.4 Time and date of recording
You can recall the time, date and year of recording for every value by pressing "SINCE"
button repeatedly.
4.1.5 Bar graph indication and history
Press "HISTORY" button to show the bar graph indication of the rainfall quantities for
the last 7 days (DAILY), weeks (WEEKLY) and months (MONTHLY).
Hold "HISTORY" button to recall the value of the current time period (current day,
week or month = 0). Press "HISTORY" button again to recall all single values (1 to 6).
Press and hold "HISTORY" button and "SINCE" button for 3 seconds at the same time
to reset the memory completely.
4.2 Thermometer
4.2.1 Indoor outdoor temperature
Press "IN/OUT TEMP/SEARCH" button to show indoor (INTEMP) or outdoor (OUT TEMP)
temperature.
4.2.2 Trend pointer
The trend pointer displayed on the LCD indicates if the outdoor temperature is
increasing, steady or decreasing.
4.2.3 Maximum/Minimum function
Press "MAX/MIN" button to show the maximum (MAX) and minimum (MIN) tempera-
ture of the indoor and outdoor sensor one after the other.
Hold "MAX/MIN" button for 3 seconds to clear the recorded maximum and minimum
reading.
4.2.4 Temperature alert
Press "ALERT" button to set the temperature alert function on or off. (
the LCD if this function is on).
Hold "ALERT" button for 3 seconds to enter the Alert setting mode. Indoor tempera-
ture flashes. Press " " or " " button to select indoor or outdoor temperature for the
temperature alert. Press "ALERT" button to confirm the settings. Press " " or " "
button to set the upper temperature limit (upwards arrow
"ALERT" button to confirm the settings. Press " " or " " button to set the lower
temperature limit (downwards arrow
When passing or falling below the selected temperature limit an alarm signal will
sound for 5 seconds and the temperature display begins to flash. The alarm signal
keeps on beeping every minute as long as the temperature is higher/lower than the
preset value (5 times maximum) or the "ALERT" button is pressed.
Attention: Is the temperature within the preset limits the display stops flashing.
10
, automatic reset 30 minutes after rain has finished
is flashing). Press
is flashing).
MONSUN
– Wireless rain gauge
5. Positioning of display unit and transmitter
The outdoor sensor unit should be securely placed on a horizontal surface in an open
area. Avoid trees or other coverings where rainfall may be reduced causing inaccurate
reading.
Place the display unit at the final position. Avoid the vicinity of any interfering field
like computer monitors or TV sets and solid metal objects.
Check the transmission of the signal from the transmitter to the display unit (trans-
mission range 30 m free field, within ferro-concrete rooms, especially with metal parts,
the received signal is naturally weakened.
If necessary chose another position for transmitter and/or display unit.
6. Battery Replacement
When the batteries in the outdoor sensor unit are used up, low battery icon appears
on the LCD of the display unit.
Use alkaline batteries only. Observe correct polarity. Low batteries should be changed
soon to avoid the damage resulting from a leaking battery.
Attention:
Please do not dispose of old electronic devices and empty batteries in household
waste. To protect the environment, take them to your retail store or to appropriate
collection sites according to national or local regulations.
7. Notes
Always read the users manual carefully before operating the unit.
Please switch off the display unit if not using it for a long time. Press "RAIN" button
and "SEARCH" button at the same time.
Use a pin to press the "RESET" button if the unit does not work properly.
Avoid placing the clock near interference sources/metal frames such as computer or TV sets.
Do not expose the instrument to extreme temperatures, vibration or shock.
8. Liability Disclaimer
The product is not a toy. Keep it out of reach of children.
appears on
The product is not to be used for medical purpose or for public information, but is
determined for home use only.
Improper use or unauthorized opening of housing will mean the loss of warranty.
No part of this manual may be reproduced without written consent of TFA Dostmann.
9. Specifications
Measuring range:
Indoor temperature:
Outdoor temperature:
Rainfall quantity:
Batteries:
-10...+50°C (14...+122°F)
-50...+70°C (-58...+158°F)
0...9999 mm (0...999.9 inch)
3 x 1,5 V AA for main unit and
2 x 1,5 V AA for transmitter (included)