BEATRICE AND KARIN SPACERS

Models " BEATRICE" and "KARIN" feature 4 spacers at the back which delimit the minimum distance to be maintained from any rear support.
The spacers must not be removed.

HOT AIR DUCTING

The pipe used for ducting the hot air must have an internal diameter of 80 mm, be insulated and protected against heat loss.
INSTALLATION OF THE RELEVANT PIPES USED FOR DUCTING THE HOT AIR MUST BE PERFORMED BY QUALIFIED
STAFF AND/OR THE MANUFACTURER'S TECHNICAL AFTER SALES ASSISTANCE

BEATRICE KARIN

Models " BEATRICE" and "KARIN" can be ducted at the back (1), to the side (2) or at the top (3), for further details relating to installation refer
to the instruction sheet included in the machine.
There is the possibility to decide when to use the ducting by manually diverting the hot air ow, using a key, supplied, which can be inserted
in the relevant housing located on the upper part of the stove.
BEATRICE
By turning it counterclockwise (position "C") part of the air is conveyed into the ducting, by turning it clockwise
(position "A") the ducting is conveyed into the room.
It is possible to use single ducting as required.
KARIN
By turning it counterclockwise (position "C") the air is conveyed into the ducting, by turning it clockwise
(position "A") the air is conveyed into the room.
It is possible to use single ducting as required.