INSTALLATION
2.

Water Connection

The hot water inlet should always feed the check valve with a
red marking (normally on the left), the cold water inlet feeds the
check valve with a blue marking (normally on the right). Should
the need arise, such as in a back to back installation, it is pos-
sible to reverse the hot and cold water inlet positions by
simply interchanging the check valves.
Ensure all piping is free from debris and
dirt to prevent blockage in the mixer.
This diverter can be used in a 2 or 3 way configuration. Open
the third (top) outlet according to need.
Outlet#1 and #2 must always remain open.
In rare cases, the plugged bottom outlet can also be
used but an extra on/off value must necessarly be
included on this circuit.
Once all water connections have been made, pressurise the
system to check for possible leaks and after turn-off the check
valves.