Error Code

Problem
E00
Safety key not plugged-in.
E01
No signal from control board to
console.
E02
Fuse or abnormal motor function.
E03
No sensor signal for 10 seconds.
E04/E06
Incline self-check failure.
E05
Current overload protection.
E07
Parameters lost or mixed-up.
E08
Control board malfunction
(EEPROM damage).
Solution
1. Insert the safety key correctly.
2. Replace the safety key or the safety key base. If it still
does not work, replace the console.
1. Check the cable connection between console and
control board if connected correctly or damaged.
2. Remove and re-insert the IC which can be found on
the control board.
3. Check the power connection of the control board.
4. Change the control board.
1. Check if the fuse is inserted correctly.
2. Check if the power cable is plugged into the wall
outlet correctly.
3. Check motor connections.
4. Replace the motor
5. Breakdown of the IGBT, replace the power cable or
control board.
1. Check if the sensor plug is plugged-in.
2. Check if the magnetic sensor is broken or damaged,
replace the magnetic sensor.
1. Check if the incline motor cables are plugged-in.
2. Check if the incline motor cables are broken, replace
the cables or incline motor if needed.
3. Replace the control board.
1. Check if the fuse is inserted correctly.
2. Check if there is any damaged cable.
3. Check the tension of the running belt, adjust if
needed.
4. Check if the running deck is lubricated.
5. Check or replace the motor.
1. Replace the control board
1. Replace the control board