5.- RECEPTION OF THE GOODS

Upon receipt of the pump, a visual check should be made to determine if any damage occurred during
transit or handling. The main items to look for are:-
a) Broken or cracked equipment, including base, motor or pump feet and flanges.
b) Bent shaft
c) Broken motor end bells, bent eyebolts or damaged boxes of motor
d) Missing parts.
e) Pump shaft rotates freely.
TAKE NOTE: Parts or accessories are some times wrapped individually or fastened
to the equipment. If any damage or losses have been incurred, promptly notify your
BOMBAS IDEAL S.A. representative, BOMBAS IDEAL S.A. Dealer and the transport
company who delivered the pump.

6.- STORAGE

The pumps should be stored in well-ventilated zones free of damp.
For short storage periods the machined parts should be protected with an oil or anti-corrosion product.
If the pump is to be left for longer periods in the store, precautions should be taken to prevent the pump
from corroding by using an anti-corrosion product, also proceeding to cover up the suction and delivery
flanges. Turn the shaft by hand every 15 days to prevent any possible seizing up.
TAKE NOTE
Make sure that the diesel engine or electric motor is not exposed to atmospheric
agents not compatible with its degree of protection which might cause damage to this.
Before storing a pump, which has recently been installed, proceed to clean and then air-dry it (do not
used hydrocarbide-based products).

7.- MANIPULATION

For handling the equipment appropriate lifting and transport systems complying with safety
norms should be used.
To handle the bare shaft pump use a sling going under the bearing supports so as to ensure stability
during lifting and displacement. Under no circumstances use the ring located over the pump.
The electric motor should be handled using the securing point(s) provided for this purpose consisting on a
ring located at the top of the casing (for motors with feet).
For diesel engines see the specific manual supplied with them.
To handle the motor pump set use a sling going under the bed so as to ensure stability during lifting and
displacement. Under no circumstances use the ring located over the motor or pump.