pliance with the lowest heating element at least
Never install the appliance:
- immediately below or in front of a power socket
or a junction box (Fig. 6)
-
-
als or pressure vessels.
Make sure there are no pipes or electric wires in the
wall which could be damaged while mounting the
appliance.
3.1 WALL MOUNTING
Make sure the screws and anchors included in the
mounting pack are suitable for the type of wall on
which you are mounting the appliance. If in doubt,
During installation, make sure the power cable is
disconnected from the power line.
To mount on the wall, see from page 225 of these
instructions.
The appliance is equipped with a sensor which can
detect an open window, if present in the proximity
of the towel warmer. For a proper operation, it is
strongly recommended to comply to the installa-
tion directions reported in Ch. 4.5.2. before wall
mounting.
3.2 MOVING THE CONTROL PANEL
If you think the position of the Control Panel is not suitable
you can move it using the free pins located on the rear of the
unit.
ing the unit to the wall to ensure proper mounting
and functioning of the Control Panel.
To move the Control Panel:
– unscrew the two screws (be careful not to damage or drop
the Control Panel)
– remove the protective caps from the selected pins
–
screws taking care not to damage it
– insert the protective caps on the free pins.
– make sure the Control Panel and Command communicate
properly.
(Fig. 4)
-
-
IMPORTANT!
position the Control Panel so that the display is fac-
ing you and the infrared transmitter is facing the
Command.
3.3 ELECTRICAL CONNECTIONS
WARNING
To be installed by a specialised engineer in accord-
ance with the applicable standards in the country
concerned.
When the appliance is installed, make sure the
power is off and the mains switch is in the "O" po-
sition.
The appliance requires a 230 V ~ 50 Hz power sup-
ply. Make sure the power line is appropriate for the
data given in table 1.
disconnecting switch allowing the appliance to
be disconnected completely from the household
mains, included the Pilot Wire, when present, in
accordance with the wiring rules.
If the appliance is installed in a bathroom, the power
residual current protection device). The power sup-
ply line and Pilot Wire control unit must be protected
by the same RCD.
Permanently connected appliances must be con-
nected using a connector block placed within a
proper junction box.
When installing the appliance in damp rooms
(kitchen, bathroom), the point of connection with
the household mains must be at least 25 cm from
lously.
If the Pilot Wire is not connected to the
programming unit, it must be terminat-
ed and insulated. Under no circumstanc-
es should the Pilot Wire be connected to
the earth.
17