2. Assembly & Installation
Make sure the national standards and prescriptions for assem-
bly and installation are observed. Installation must be carried
out only by qualified technicians.
The following items must be checked prior to installation:
• A max. operating pressure of 1000 K Pa (10 bar) must not be exceeded
• The max. ambient temperature is 40° C
• The max. water temperature is 25° C
• The max. flow rate must not be exceeded (see section 2.1.)
• The installation site of the reactor must be frost-protected and dry

2.1. Reactor

The following reactor types are available in the Aquada series:
Type
Length
1
470 mm
2
670 mm
4
670 mm
7
1030 mm
10
1030 mm
Flow rate: 400 J/m
*
6
Diameter
Connections
70 mm
70 mm
101,6 mm
101,6 mm
140 mm
, UV-Transmission: 94 %
2
Min. free space
above reactor
R 1/2
370 mm
R 3/4
570 mm
R 3/4
570 mm
R1
920 mm
R1 1/2
920 mm
Max. flow rate
*
m
/h
3
0,70
1,77
3,01
6,20
9,00