• Press Reset button for approx. 10 seconds after having switched on the unit, until
you hear a signal
• The unit is now in the warm up phase. After 5 minutes the solenoid valve is
switched on and fully opened.
• Now open the stop valve slowly but completely. At the same time a water tap is
to be opened to ensure that the rest of the air escapes from the unit.
3.1.1. Units without Solenoid Valve
• Open a water tap
• Open slowly the main water tap of the domestic water supply plant until the air
has completely escaped from the unit
• Insert the mains plug into the socket. The display of the Proxima and Maxima unit
shows 365 days
• Press the Reset button for approx. 10 sec. after switching on (Proxima, Maxima)
• Now the unit is in the warming up phase. After 5 minutes it has reached the
highest intensity and is ready for use.
All UV systems must only be switched on after the reactor has been filled
with water.
14
The function control of the Alti-
ma units can be seen through the
blue shiny cap.