TM7
Dip switch SW1
1
EMERGENCY
2
ELECTRO-LOCk
3
BATTERY MONITORING
4
OPENING IN BATTERY
TCA
5
INCREASE
6
FUNCTION
7
ENTRANCE
CH/PP
FUNCTION
8
ENTRANCE
STOP/ ANTI-PANIC
9
INTERLOCk FUNCTION
OPENING PRIORITY
10
(INTERLOCk)
11
INSIDE SENSOR TEST
12
OUTSIDE SENSOR TEST
Dip switch SW2
1
2
AUTO CLOSE
DELAY
ON
Enables opening with always closed program.
OFF
Disables opening with always closed program.
Enables the electric lock when the automation is closed, regardless
ON
of the selected program.
Enables the electric lock when the automation is closed only with
OFF
the "always closed" program.
If there is no voltage, the automation performs the manoeuvres
ON
normally. If the battery is flat, the board switches off.
If there is no voltage, the automation performs the manoeuvres
OFF
normally. Before the battery is fully discharged, it performs an
opening manoeuvre.
In the event of a power failure, the automation opens and remains
ON
open until the mains voltage is restored (DIP3 must be OFF)
In the event of a power failure, the automation performs the ma-
OFF
neuvers normally.
With a high flow of passages, the automatic closing time is auto-
ON
matically increased.
OFF
Function disabled, the automatic closing time remains unchanged.
ON
OFF
Keep the Dip switch in OFF
ON
Enables the Step-by-Step function on input 20.
OFF
Enables the CLOSING function on input 20.
ON
Enables the STOP function on STOP/ANTI-PANIC input.
OFF
Enables the ANTI-PANIC function on STOP/ANTI-PANIC input.
ON
Enables INTERLOCK function
OFF Disables INTERLOCK function
With ACTIVE INTERLOCK function. Set in ON on the control board
ON
that must have LOW priority.
With ACTIVE INTERLOCK function. Set in OFF on the control board
OFF
that must have HIGH priority.
Enables internal sensor test – the test is performed on the input
ON
- and + TEST of the connector J19.
OFF
Disables the test on the input of the connector J19.
Enables external sensor test – the test is performed on the input
ON
- and + TEST of the connector J20.
OFF
Disables the test on the input of the connector J20.
ON
OFF
Keep the Dip switch in OFF
ON
OFF
Keep the Dip switch in OFF
Adjusts Auto Close Delay.