tau DC20 Notice D'installation page 22

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
N.B.: With DIP9 ON the input of terminal 24 (Stop / Antipanic) changes use. See Interlock Function.
CONNECTOR J17:
25 - 26
MECHANICAL SWITCH
27 - 28
WARNING: In case neither the mechanical selector it is necessary to jumper wire
terminals 25 - 27.
SM
0419
M1
M2
1
2
3
4
CONNECTOR
J9 -
CONNECTOR
J10 -
CONNECTOR J10:
Terminals
4
AUTOMATION OpEN LIghT
5
pOSITIVE
6
INTERLOCk OUTpUT
7
COMMUN
CONNECTOR J11 - battery charger board connector.
CONNECTOR J12 - not used.
CONNECTOR J13 - battery connector.
CONNECTOR J14 - transformer primary connector.
CONNECTOR J15 - 230V 50Hz supply input connector.
CONNECTOR J6 - transformer secondary connector.
JUMPER J18 - 12/5 VDC encoder supply selection (leave it on 12 Vdc as settled in the factory)
CONNECTOR J15:
Terminals
1
25= Commun
26= Switch B0
27= Switch B1
28= Switch B2
HOLD OPEN =
WINTER OPENING =
AUTO =
EXIT ONLY =
LOCK =
electric block connection (12V DC).
output connection.
Input/Output
Input/Output
PHASE
Connections:
Selector
1
2
3
4
Keeps door fully open.
To have a reduced
All Opening Inputs enabled-
Disables Outside Radar.
Keeps door closed, allowing opening
only with EMERGENCY Input (with Dip
#1 on SW1 on ON).
Description
24V DC, max. 3 W
24v cc
INTERLOCK CONTACT
COMMUN INTERLOCK CONTACT
Description
230V AC
22
Control Panel
25
26
27
28
aperture.