Designation
Operating voltage
Speed
Grinding capacity at
200-240 V / 50/60 Hz
100-115 V / 50/60 Hz
Sound pressure level
maximum permitted operating
time
Dimensions W x H x D in mm
Weight
Capacity of the hopper

TROUBLESHOOTING

The following information should help you deal with operational problems. If you are unsuccessful,
please obtain the help of an authorized service partner.
Problem
The grinder does not
start. The indicator
lamp (pos. 7) does
not light up.
The grinder does not
start or runs for only
a short time. The
indicator lamp (pos.
7) blinks.
22
ProM
200-240V / 50/60Hz (e.g. Europe)
or
100-115 V / 50/60 Hz (e.g. USA, Canada, Japan)
1650-1850 rpm
1,9-8,7 g/s (fine to coarse)
1.3-7.5 g/s (fine to coarse)
60 dB when running empty
80 dB when grinding
S3 20% (e.g. 6s ON, 24s OFF).
162 x 370 x 270
6 kg
Approx. 260 g
Cause
The plug is not
plugged in or there
is no electricity
supply to the power
socket.
The fuse is blown.
The grind size is too
fine.
Solution
Insert the plug into the socket or plug the grinder
into another socket.
1. Pull out the plug.
2. Using the supplied screw driver screw out the
bracket holding the fuse on the bottom of the
grinder.
3. Replace the fuse with a new one of the type
"T 1,8A L" (200-240V) or "F 2,5A L" (100-115V).
4. Screw the fuse bracket back in.
1. Use the adjustment button (pos. 3) to set to
maximum grind size - coarse.
2. Clean the spout if necessary with a spoon
handle.
3. Start a grind operation.
The grinder grinds itself free.
4. Start another grind operation and set the de-
sired level of grind size.