9.4

Piping diagram for refrigerant circuit

Fig. 9-3
Components in the heat pump circuit
a / R1T
Ambient temperature sensor
b / R2T
Temperature sensor (outlet)
c / R3T
Temperature sensor (extraction system)
d / R4T
Temperature sensor (heat exchanger) (distributor)
e / R5T
Temperature sensor (heat exchanger centre)
f / R6T
Temperature sensor (liquid)
g / R7T
Temperature sensor (compressor housing)
h / R8T
Temperature sensor (compressor connection)
i / R9T
Water inlet temperature sensor
j / R10T
Water outlet temperature sensor
k / Y1E
Electronic expansion valve (main)
l / Y3E
Electronic expansion valve (injection)
m / Y1S
Solenoid valve (4-way valve)
n / Y2S
Solenoid valve (hot gas bypass)
o / Y3S
Solenoid valve (low-pressure bypass)
p / Y4S
Solenoid valve (injection bypass)
q
Screw connection 1" M
r / E1 H HEX
Solenoid valve
s
Pressure relief valve
t
Crankcase heater
u
High-pressure switch (5.6 MPa)
v
High-pressure switch (4.17 MPa)
w / S1PL
Low-pressure switch
x
High-pressure sensor
y
Preheater
z
Fan motor
aa
Silencer
ab
Filter
ac
Compressor
ad
Safety valve
ae
Capillary tube
af
PCB – cooling
ag
Service connection -5/16" – Light signal
ah
Clamped pipe
ai
Heating
aj
Cooling
ak
Gaseous
al
Liquid
am
Water inlet (return)
an
Water outlet (feed)
ao
Hot water storage tanks
Daikin Altherma ETS(X/H)(B)-D
Heat pump (indoor unit) with integrated heat accumulator
008.1447299_00 – 06/2019 – EN
9.5

Hydraulic connection

DANGER: RISK OF BURNING
High temperatures can occur in the solar storage tank.
Therefore, sufficient scalding protection must be included
when the hot water system is installed (automatic hot water
mixing device).
To avoid heat losses due to gravity flows, the devices can
be optionally equipped with plastic circulation stop valves.
These are suitable for maximum operating temperatures of
95 °C and for installation in all heat exchanger connections
on the storage tank side (except heat exchangers for pres-
surised solar system charging).
Suitable circulation stop valves must be installed in the
building for components connected to the heat exchanger
for pressurised solar system charging.
9.5.1

Hydraulic system connection

INFORMATION
The system diagram below is an example, and is never a
substitute for careful system planning. Please visit our
website for more diagrams.
9
Technical data
Installer reference guide