M-system MFCD 95 Série Mode D'emploi page 194

Cuisiniere maxi avec double four
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONNECTING THE FEEDER
CONNECTING THE FEEDER CABLE
CABLE
To connect the feeder cable to the cooker
it is necessary to:
To connect the feeder cable to the cook-
er it is necessary to:
– Remove the two screws that hold shield
"A" behind the cooker.
– Remove the two screws that hold
shield A behind the cooker.
– Open completely the cable clamp "D".
– Open completely the cable clamp D.
– Position the U bolts onto terminal block
"B" (fig. 10.1) according to the diagram
– Position the U bolts onto terminal block
in figs. 10.2a, 10.2b, 10.2c.
B (fig. 10.1) according to the diagram
in fig. 10.2a, 10.2b, 10.2c.
– Insert the feeder cable into the cable
clamp "D". The supply cable must be of
– Insert the feeder cable into the cable
a suitable size (see the section "Feeder
clamp D. The supply cable must be
cable section").
of a suitable size (see the section
"Feeder cable section").
– Connect the phase and earth cables to
terminal "B" according figures 10.2a,
– Connect the phase and earth cables
10.2b, 10.2c.
to terminal B according figures 10.2a,
10.2b, 10.2c.
– Pull the feeder cable and block it with
the cable clamp "D".
– Pull the feeder cable and block it with
the cable clamp D.
– Re-mount shield "A".
– Re-mount shield A.
N.B. The earth conductor must be left
about 3 cm longer than the others.
N.B. The earth conductor must be left
about 3 cm longer than the others.
230 V~
1
2
3
4
L
1
1
2
3
4
N(L
L1
Fig. 10.2a
194
5
N
PE
(L
)
2
5
)
2
PE
Fig. 10.2b
Fig. 10.1
FEEDER CABLE SECTION
Type "HO5RR-F"
~
230 V
400 V 2N
400 V 2N
(*) – Connection with wall box connection
400 V 2N~
1
2
3
4
5
L
L
N
N
PE
1
2
1
2
1
2
3
4
5
L2
N1
N2
L1
PE
D
3 x 2,5 mm
~
5 x 1,5 mm
~
4 x 1,5 mm
400 V 2N~
1
2
L
1
1
2
3
L2
L1
Fig. 10.2c
B
A
(*)
2
(*)
2
(*)
2
3
4
5
L
N
PE
2
4
5
N
PE

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mfntkn 95 serie

Table des Matières