Installation of cables
Wiring of the sensor should be routed separately or screened from heavy conductor lines, as in ex-
treme cases inductive peak voltages can destroy the sensors despite the integrated protective circuit.
Screened cable or twisted lines are recommended, especially for longer cable runs > 5 m. Direct control
of electric light bulbs is to be avoided, because during the switch-on moment cold current is many times
the rated current and can destroy the output stage of the sensor.
Units with strong fields nearby, e. g. high power walkie-talkies, or noise sources in the lower fre-
quency range, e. g. long, middle or short-wave transmitters should not be operated close to the sensors
or additional measures have to be taken in order to eliminate incorrect operation.
Technical data
Technical data*
Output function
Operating voltage (U
Permitted residual ripple max.
Load resistance (R
)
L
Power consumption (outputs no-load)
Analogue output (switchable)
Operating current (I
e
Permitted ambient temperature
Permitted product temperature
LED-display
Degree of protection IEC 60529
Connection
Process connection / connection head
Lid
So far applicable. Further technical data: See data sheet.
**
Ambient temperature in °C
60
50
40
30
20
10
0
-30
0
-10
-20
-30
)
B
)
Prozess
Elektronik
-25
-25
90
180
180
-25
0
30
60
0
4...20 mA (20...4 mA) / 0...10 V (10...0V)
Flange connector M 12 x 1 (5 - pin)
-25
VA No. 1.4305 (AISI 303) / Aluminium
55
55,00
40
-25
-25
90
120
150
180
180
Analogue
18...36 V DC
25 %
≤ 600 Ω
3 W
0...250 mA
-25...+55 °C
-25...+180 °C**
Green / blue
IP 65
Aluminium
Product temperature in °C