4.5 Inflating by mouth
WARNING
Never inflate the flotation device by mouth and trigger the CO2 cartridge afterwards.
This may cause over-inflation and serious damage.
Never fill buoy with other gases!
Do not fill buoy with the help of an inflation device (e.g. pneumatic pump)!
Please avoid inhaling the CO2 gas from the flotation device when topping up the buoy
via the oral valve.
•
Remove buoy from pocket.
•
Open the Velcro on the safety leash and unwrap safety leash.
•
U nfold buoy completely.
•
O pen the cap of the oral valve.
•
Inflate buoy with your breath using the valve.
4.6 How do I make RESTUBE ready for its next use?
Once RESTUBE has been triggered, it must be made ready to be used again. You will
need an original RESTUBE-CO2-Cartridge with a securing clip.
WARNING
Only the original RESTUBE-CO2-Cartridges are 100% quality-certified,
seawater resistant and the force is tailored to the RESTUBE trigger!
Do not use comparable commercial CO2 cartridges!
These will not guarantee inflation of RESTUBE in an emergency.
The CO2 cartridge (#1)
RESTUBE only guarantees functionality when using the original
RESTUBE-CO2-Cartridge.
•
Remove any dirt (e.g. sand).
•
Remove protective cover from the CO2 cartridge.
•
Unscrew the empty CO2 cartridge and dispose of with residual
waste.
•
Fold away release lever to avoid piercing the new CO2 cartridge.
•
Place the new green securing clip on the red indentation on the
trigger mechanism.
•
Screw the new original-RESTUBE-CO² cartridge tightly and up
to marking into the trigger mechanism.
•
Slide protective cover onto the CO2 cartridge.
The buoy
NOTICE
Pointed or sharp objects can damage the valve! The buoy can only be folded away
correctly when there is no gas in it.
#1
21