Special Functions - Watts BT-M6Z02-RF 230V Guide Utilisateur

Masquer les pouces Voir aussi pour BT-M6Z02-RF 230V:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BT-M6Z02 RF
Press > for 5 seconds, all channel leds
must blink Red. Product is waiting for
link.
Note: To exit, press > for 5 seconds.
BT-CT02-RF
BT-CT02 RF
Link « Circuit » device
Be careful! Link BT-M6Z02-RF to BT-CT02-RF, once ALL thermostats to BT-M6Z02-RF have been linked.

7 SPECIAL FUNCTIONS

Humidity management
This feature is available on thermostats that have Humidity sensor (BT-D02RF RH and BT-DP02RF RH).
Please refer to thermostat instruction manual to correctly set the parameters.
-
If there is a humidity default (dew point or thumidity threshold), then cooling on the zone is stopped (stops flow
in the zone).
-
If in the installation there is a BT-HCM02-RF and dehumidifier is active then if there is humidity default,
dehumidifier is active
Pump Delay (not configurable)
To avoid pump damage and noise in hydraulic circuit (Water flow in the pipe) the start-up of the pump will be
delayed for 1 minute after a heating demand from the zone thermostats. This delay should allow the actuator to
be completely opened open before the activation of the pump.
Valve exercise (not configurable)
To prevent the valves from seizing, each valve is automatically activated 2 minutes per week.
Factory settings function:
Use this function to erase all configurations, RF links and restore factory settings.
In 'Run mode', press in the same time during 5 seconds the 2 keys (◄) and (►).
Then the product has been resetted.
BT-CT02 RF
Link as a normal zone
BT-WR02-RF
BT-WR02 RF
Put product in RF Link mode.
10
In this configuration, BT-WR-
WR02-RF is used as hydraulic
circuit device:
Refer to the instruction manual of
BT-CT02-RF for further
explanation.