CONNECTIONS

��
The connections must be set up by a technician that is qualified and/or authorised by the Manufacturer.
��
By the installer the type of cable, with relative section, to be installed in case of replacement is: H05RR-F sez.3G0,75

Chimney connection

The chimney must be sized so as to guarantee the draught declared by the Manufacturer.
The boiler must be connected to a single flue. It is forbidden to connect the boiler to a flue shared with other combustion
appliances or with hood exhausts.
The flue must be inspectable for cleaning.

Components

This boiler is equipped with the following control and safety components:
3 bar safety valve;
Booster pump control thermostat (integrated in the functions of the electronic board);
Acoustic alarm activation thermostat (integrated in the functions of the electronic board);
Temperature indicator (integrated in the functions of the electronic board, with display);
Pressure indicator (integrated in the functions of the electronic board, with display);
Acoustic alarm (integrated in the functions of the electronic board);
Automatic regulation thermal switch (integrated in the functions of the electronic board);
Automatic blocking thermal switch (manual reset thermostat);
Circulation system;
Expansion system (Expansion vessel).
Local laws and regulations (for example the UNI 10412-2 standard valid in Italy) could provide for other safety components. In this
case they must be mounted in the system.
The construction of a heating system with the relative installation of the boiler must comply with all national and local regulations in
force in the place where the system is carried out.

Boiler-system connection

Connect the boiler to the hydraulic system so as not to constrain it excessively and to allow it to move slightly.
��
Before connecting the boiler, it is strongly recommended that the system be thoroughly washed in order to eliminate residues
and deposits.
Use and maintenance manual HR EVO Smart
3/4" Flow
Ø15 Safety drain
3/4" Return
Boiler system air
venting valve
Delivery pipe with
connections
Pressure transducer
Pressure relief valve
Hight efficiency
circulating pump
Return pipe with
connection
Membrane expansion
tank