EN
Rev.1 08/09/2021
Pag.20
Automatic cleaning system
The boiler is equipped with atuomatic brazier cleaning system. This means that there is no need to carry out daily manual cleaning
of the brazier or every time the boiler is lit. The automatic cleaning system is activated every time the boiler is lit and after 6 hours
of continuous operation. The cleaning cycle, which involves shutting down, automatic cleaning and restarting the boiler, takes about
10 minutes. During this period the heating is guaranteed by the heat accumulated by the appliance itself.
Note: the times indicated are those set by default by the Manufacturer.
⚠
Recharge the fuel
⚠
Use only wood pellets, the characteristics shown in this manual.
During pellet loading prevent the pellet bag from coming into contact with hot surfaces.
It is not recommended to empty the pellet bag directly into the hopper to avoid depositing wood sawdust on the bottom of
the hopper.
To load the pellets inside the hopper, proceed as described below:
step
1
Open the pellet hopper cover
2
Pour the pellets into the hopper
3
Close the pellet hopper cover
When the pellet is running out, the signal appears on the display thanks to the sensor with which the boiler is equipped.
Doors opening
Open the outer door to gain access to the combustion chamber part and the ash compartment part.
The door can be opened using the handle provided.
The combustion chamber door and the ash drawer can only be opened when the boiler is in the OFF state.
If one of them is not closed, the pellet supply is interrupted.
If the combustion chamber door, the pellet hopper lid and / or the ash drawer are not closed within 1 minute, the boiler switches off
signaling ALARM M.
Opening the doors also interrupts the automatic cleaning phase of the brazier. In the event of a prolonged interruption of the cleaning
phase, ALARM N may appear.
Remember that in the presence of an alarm the boiler will have to be restarted manually.
User training
Once installation is complete, the user must always be fully trained in the functions and characteristics of the boiler by the technician
authorized by Ravelli to ensure optimal and safe use.
The training should cover the following topics:
•
Description of the boiler, its operation and basic settings
•
How to turn the boiler on and off safely
•
Fuel storage and refilling
•
What to do in the event of an alarm, in particular that of "no ignition"
•
How to clean the boiler correctly and the importance of performing it on a regular basis
•
It is advisable to schedule the first annual maintenance
Use and maintenance manual HR EVO Smart