Control panel
Overview of oper-
ating modes
Overview of oper-
ating statuses
1
2
3
Control panel behind the lockable access flap
a
button
b
button
c
button
d
Green LED
Flashes when starting/ready for use, lights up during operation.
e
Yellow LED CO
2
Flashes in the event of a CO
active.
f
Red LED
Flashes in the event of a fault.
Manual mode
During operation, the fan speed can be changed individually between 20–100 %
in 5 % increments via the and buttons.
Optional initial flow can be switched on before normal operation.
Manual+time
Same as
mode
used to set a switch-on time and switch-off time for each day.
CO2 mode
The fan speed is automatically regulated according to the set room size. The need
for ventilation is indicated via an LED and a display message.
Optional initial flow can be switched on before normal operation and a circulation
function can be activated.
CO2+time mode
Same as
to set a switch-on time and switch-off time for each day.
The following operating statuses are shown in the display:
Ready for opera-
The power supply has been connected and the appliance is ready for operation.
tion
Flow
The fan runs at a set flow rate and duration to clean the air before the air purifier
switches to normal operation.
Manual opera-
The appliance is in normal operation.
tion
Manual+time
operation
CO2 operation
CO2+time oper-
ation
ThermoControl
Relevant pathogens are deactivated automatically by Miele ThermoControl after
every use.
active
Fan run-on
The fan keeps running after Miele ThermoControl in order to cool the filter.
Intensive circ.
The fan runs at a higher speed for a short period in order to quickly circulate the
air within the room.
active
en - Using the machine
6
5
4
warning, lights up when heating is
2
Manual mode
but with additional clock function (timer) which can be
CO2 mode
but with additional clock function (timer) which can be used
45