Semina Life | 119461-0000 w | v4.1 | 2020-04-22 | Montageanleitung | Montagehandleiding | Instructions for assembly | Instructions de montage
General
Please read these instructions and observe their contents and
warnings before assemble the equipment!
Intended use
Semina Life is a sun protection awning that can only be used for this
purpose. Misuse can lead to hazards, damage or to collapse of the
awning and is not permissible. Changes, additions may only be carried
out with the written permission of Weinor. Prohibited changes to the
awning will result in voiding of the guarantee claims.
CE mark
Weinor GmbH & Co. KG declares that
the Semina Life is in compliance with
the basic requirements and relevant
provisions of the EN standards. Semi-
na Life meets the requirements of the
wind resistance class indicated in the
CE conformity marks. The requirements
shall only be deemed as having been
met once the manufacturer's instructions
have been adhered to.
Qualifications
These instructions are addressed to trained fitters and require qualifica-
tion and knowledge of installation techniques:
- Occupational safety at work, operating safety and accident prevention
regulations
- Handling of ladders, scaffolding, tools and machines,
- Transport of long, heavy components and glass panes,
- Estimation of the building structure and fitting the fixing materials,
- Installation, start-up and operation of the product.
Employ a professional installation company if you do not possess these
qualifications!
Safety symbols
Warning! Risk of electric shock!
Careful! Personal injury!
Caution! Product and property damage!
Safety instructions
Warning! Risk of electric shock!
Follow the warning instructions for the prevention of electrical shock!
Electrical fixed installation may only be carried out by electrically skilled
person according to VDE 100!
Observe the installation instructions for the electrical devices included
in the delivery!
Separate the electrical connections from the mains during the instal-
lation!
Only connect electrical termination to mains system with all-pole dis-
connecting device and with min. 3 mm contact opening width!
Only connect the construction if indications on product relating to
voltage, frequency and output match those of the power source!
Caution! Personal injury!
Follow safety instructions in order to prevent personal injury!
Observe the instructions for installation and setting from the manufac-
turer of the drive, switch / control!
Keep packaging, sheeting and small parts away from children (choking
hazard)!
Disconnect current supply when working within the movement range
of the construction (disconnect connector coupling on driver or install
controlled power interruption from the outside)!
Technische Änderungen vorbehalten | Technische wijzigingen voorbehouden | We reserve the right to make technical changes | Sous réserve de modifications techniques
weinor GmbH & Co. KG
Mathias-Brüggen-Straße 110
50829 Köln
15
EN 13 561
Markise für die Verwendung
im Außenbereich
Windwiderstandsklasse:
Klasse 2
Danger level III
Danger level II
Danger level I
Switch off fuses and automatic control in order to prevent risk of crus-
hing or falling due to uncontrolled movements of the construction!
Ascending aids:
Do not lean ladders against the awning or fix them to the awning!
Ladders must be on a firm base and provide adequate support!
Only use ladders with adequate load-bearing capacity!
Anti-fall guards:
Use appropriate anti-fall guards to prevent the danger of falling espe-
cially when working at considerable heights!
Mounting brackets:
Check that the type and number of the mounting brackets supplied
are compliant with the order!
Check that the information provided in the order about the installation
surface tallies with the actual installation surface on site! Installation is
inadmissible in case of safety-relevant deviations!
Fixing material:
Use suitable installation and fitting materials (plugs, bolts, resin etc.)
corresponding to onsite conditions and loads!
Check that the awning is fitted with the type and number of brackets
recommended by the manufacturer.
Check that the awning is installed using the fixings extraction forces
recommended by the manufacturer, and the manufacturer's guide-
lines on dowels are observed when performing the installation work!
Crushing and shearing zones:
Crushing and shearing zones exist between movable components
and moving awnings parts (projection profile, housing, folding arms,
profiles) which could catch and draw in clothing or body parts!
Only activate awnings up to 2.5 m installation height or awnings
above accessible traffic routes if the moving parts are within your line
of vision! Electrical controls, radio controls with latch switches, stand-
alone latch switches, etc. are not permissible in this case!
The key switch must be fitted in the line of vision of the projection
profile, but far enough removed from the movable parts, at a height
of 1.5 metres (national regulations relating to disabled people must be
observed)!
Partly mounted awnings:
In awnings which are partly mounted in the factory, secure the spring-
tensioned parts (designated by the manufacturer) against unintentio-
nal opening.
Caution! Do not remove this locking device until the installation of the
awnings has been completed in order to prevent the high risk of injury
that could result from unintentional opening of spring-tensioned
parts!
Test run:
When ascending the awning for the first time, the working range of
the awning and the area below it must be kept clear!
A visual inspection of the fixing material and brackets must be perfor-
med after the awning has been extended for the first time.
When carrying out test runs, never use automatic system control or
switches if the awning is not in the operator's line of vision!
Use the test lead for the testing and commissioning of the awning.
Caution! Product and property damage!
Secure cargo properly and safely!
Protect the packaging from moisture (dampened packaging can loo-
sen during transport)!
Seal open packaging for further transport!
The awning must be carried to the place of installation the right way
round so it does not have to be turned round again in a confined
space.
Raise the awning to a higher level using ropes:
Remove awning from the packaging and secure tightly with hauling ropes!
Lift the awning horizontally and evenly!
- Tool list → weinor Downloadcenter (DLC)
- Exploded drawing → weinor Downloadcenter (DLC)
7