INSTALLATION
INSTALLATION
·
Place the airco on a solid and stable floor, this way you will prevent excessive noise
and vibrations. Make sure that the floor is strong enough to support the weight of
the appliance.
·
The appliance has small wheels for easy moving. Make sure only to move the airco
over a flat and level surface. Be careful when moving the airco over carpet. Never
roll the unit over an object.
·
Place the unit near an earthed socket.
·
Mount the cable storage accessory on the back of the unit.
·
Never place any object within 30 cm round the airco.
·
Make sure that the air outlet is brought out with the hose. Keep the opening to the
outside as small as possible so that no warm air from the outside can come back
inside.
·
Make sure there is a free surrounding of at least 50 cm around the outlet.
·
Make sure the air outlet hose isn't bend during use.
INSTALLATION OF THE WINDOW KIT
The air outlet hose must be used in the "cool" or "auto" mode.
During the "fan" or "dry" mode, you don't need to attache the air
outlet hose.
1.
Place the hose/appliance connector on one side of the air
outlet hose and the hose/window adapter connector on the
other side of the hose. The connectors snap into place as soon
as you push them onto the hose.
2.
Attach the hose to the unit. The side of the hose with hose/
appliance connector must be mounted on the air outlet at the
back of the appliance. Slide the connector into the air outlet
holders. Make sure that the hook on the connector matches
the notch above the air outlet.
3.
Place the window adapter in the window. This can be done
both horizontally and vertically. Use the window seals to close
any openings in the window. Block the window adapter at the
desired length using the supplied window adapter plug.
4.
If desired, you can fix the window with the L-iron and 2 screws.
5.
Attach the connector to the window adapter.
www.domo-elektro.be
or
or
50cm
or
50cm
max 120cm
min 30cm
50cm
or
50cm
1.
2.
or
50cm
3.
4.
5.
or
or
or
50cm
50cm
50cm
max 120c
min 30cm
max 120cm
min 30cm
51
max 120cm
DO324A
min 30cm