ATTACHMENT 2: WIND RESISTANCE CLASS
KZip blind wind load resistance class certifi cation
according to standard UNI EN 1932:2013
Palagina closely follows the legislation evolutions that concern
our products and performs frequent tests in order to defi ne the
performance characteristics. The tests are performed by indepen-
dent and certifi ed bodies,
"K.Zip" products are tested for wind load resistance in complian-
ce with the standards (UNI EN 13561:2015, UNI EN 1932:2013).
Wind resistance classes range from 0 (lowest level) up to level 6
760
Pascal
130
Km / h
Find here below KZIP Standard and KZIP Quick Lock extracts of the test certifi cation.
(Rapporto di prova n. 328559 del 22/10/2015)
Conclusioni.
In base alla prova eseguita, in base ai risultati ottenuti ed in base a quanto indicato nel paragrafo 4.1 "Re-
sistance to wind loads"
("Resistenza al carico del vento")
tuito da tenda denominata "KZIP - sistema in luce" e presentata dalla ditta PALAGINA S.r.l. - Via Palagina, 39 -
Località Ponte a Cappiano - 50054 FUCECCHIO (FI) - Italia, risulta rientrare nella classe di prestazione riporta-
ta nella seguente tabella.
Tipologia di prova
Resistenza
al carico del vento
without tension system"
I risultati riportati si riferiscono al solo campione provato e sono validi solo nelle condizioni in cui la prova è
stata effettuata.
Il presente rapporto di prova, da solo, non può essere considerato un certificato di conformità.
Il Responsabile
Tecnico di Prova
(Dott. Ing. Paolo Bertini)
............................................
24
VENTO / WIND
VENT / WIND
km / h
130
102
84
65
52
44
30
<30
segue - foglio n. 9 di 9
della norma EN 13561:2015, il campione in esame, costi-
Norma di prova
Norma di classificazione
Classe
e relativo paragrafo
e relativo paragrafo
UNI EN 1932:2013
paragrafo 7.4
"Awnings
EN 13561:2015
with lateral guiderail
paragrafo 4.1
with fabric running
"Resistance
6
into the lateral rails
to wind loads"
("Resistenza
("Tende con guide laterali
al carico del vento")
con tessuto che scorre
all'interno dei binari laterali
senza sistema di tensione")
Il Responsabile del Laboratorio
L'Amministratore Delegato
di Edilizia (Security & Safety)
(Dott. Arch. Sara Lorenza Giordano)
(Dott. Andrea Bruschi)
............................................
............................................
Firmato digitalmente da GIORDANO SARA LORENZA
(highest certifi able level, that corresponds to a reference pressure
of 480 N/mm2).
"K.Zip" blinds easily overtook class 6 reference limits and rea-
ched pressure values of 760 N/mm² , that is a value 60% higher
than the highest certifi able level.
Through a mathematical operation, we determined that this
stress is comparable to the stress exerted by the wind at around
130 km/h.
By the way, it is important to know that "wind load resistance"
is a laboratory test set up with a static pressure which does not
reproduce the real dynamic wind stress condition.
In case of extreme weather events the blind could shows critical
issues even with wind gusts at lower speed than stated.
Pressione / Pressure
Classe / Class
Pression / Druck
Classe / Klasse
Pa N/m²
PALAGINA
760
CLASSE 6
480
324
CLASSE 5
204
CLASSE 4
132
CLASSE 3
84
CLASSE 2
48
CLASSE 1
<48
CLASSE 0
(Rapporto di prova n. 328558 del 22/10/2015)
Conclusioni.
In base alla prova eseguita, in base ai risultati ottenuti ed in base a quanto indicato nel paragrafo 4.1 "Re-
sistance to wind loads"
("Resistenza al carico del vento")
tuito da tenda denominata "KZIP QUICK LOCK - sistema in luce" e presentata dalla ditta PALAGINA S.r.l. - Via
Palagina, 39 - Località Ponte a Cappiano - 50054 FUCECCHIO (FI) - Italia, risulta rientrare nella classe di pre-
stazione riportata nella seguente tabella.
Tipologia di prova
Norma di prova
e relativo paragrafo
UNI EN 1932:2013
paragrafo 7.4
"Awnings
with lateral guiderail
with fabric running
Resistenza
into the lateral rails
al carico del vento
without tension system"
("Tende con guide laterali
con tessuto che scorre
all'interno dei binari laterali
senza sistema di tensione")
I risultati riportati si riferiscono al solo campione provato e sono validi solo nelle condizioni in cui la prova è
stata effettuata.
Il presente rapporto di prova, da solo, non può essere considerato un certificato di conformità.
Il Responsabile
Il Responsabile del Laboratorio
Tecnico di Prova
di Edilizia (Security & Safety)
(Dott. Ing. Paolo Bertini)
(Dott. Andrea Bruschi)
............................................
............................................
Max certificabile
Max certifiable
Max certifiable
Max zertifizierbare
segue - foglio n. 8 di 8
della norma EN 13561:2015, il campione in esame, costi-
Norma di classificazione
Classe
e relativo paragrafo
EN 13561:2015
paragrafo 4.1
"Resistance
6
to wind loads"
("Resistenza
al carico del vento")
L'Amministratore Delegato
(Dott. Arch. Sara Lorenza Giordano)
............................................
Firmato digitalmente da GIORDANO SARA LORENZA
PALAGINA - USE AND MAINTENANCE

Publicité

Table des Matières
loading

Table des Matières