Hilti SI­-AT-­A22 Mode D'emploi Original page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Result 2 / 2
The symbols indicating "Tighten-
ing not completed correctly" are
displayed.
The LEDs flash red.
The warning tone sounds.
▶ Use a calibrated torque wrench
to apply the correct tightening
torque to the fastener.
5.10 Checking fastener
All Hilti products are subject to a process of constant updating, which means
that products not described in this documentation might also be supported
by the SI-AT module. Keep the software and the operating instructions up
to date at all times.
Other system products approved for use with this product, the latest
operating instructions and instructions for testing can be found online at:
www.hilti.group | USA: www.hilti.com
5.10.1 Checking the fasteners of stud anchors
To ensure that the specified pretension as per the approval / operating
instructions has been correctly applied when the "Adaptive" operating
mode is used to tighten stud anchors, the first stud anchor and the
last stud anchor always have to be checked with a calibrated torque
wrench. This check of the applied installation torque has to be carried
out immediately after tightening (installation) of the stud anchor.
The check torque to be applied corresponds to the installation torque
specified for the stud anchor in question; obtain this information from
the instructions for use for this anchor issued by the stud anchor
manufacturer.
*2124681*
2124681
English
15

Publicité

Table des Matières
loading

Table des Matières