3.6 Buzzer
The buzzer in the adaptive torque module emits the following signal tones
as audible feedback:
•
Long buzz: Confirmation signal (OK / operation completed successfully)
•
2 short buzzes, the LEDs flash yellow: Warning 1 (OK or, as applicable,
not OK / repeat tightening)
•
4 short buzzes, the LEDs flash red: Warning 2 (not OK / operation
aborted)
3.7 USB connection
The USB port can be used to connect the adaptive torque module to a PC.
When this connection is made, the AT Documentation Software offers a
range of functions, including:
•
Adding new data records for new fasteners
•
Changing / updating existing data records
•
Deactivating / activating the documentation function
•
Loading the log from the documentation function
•
Setting the clock in the torque module
Further information can be found in the documentation for the
AT Documentation Software.
The software can be downloaded from here:
http://www.hilti.com/adaptive_torque_documentation_software
3.8 Items supplied
Adaptive torque module, operating instructions, quick-start guide, USB
cable.
Other system products approved for use with this product can be found at
your local Hilti Store or at: www.hilti.group
4
Technical data
Weight
Bar code scanner
*2124681*
2124681
0.57 lb
(0.26 kg)
Camera / scanner (imager)
English
5