Noise/Vibration Information - Bosch GAS 12-25 Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
Automatic start/stop
MY
IN
CN
Permitted connected load of the connected power tool.
These values can differ for other country-specific models. Please take note of the information on the socket of the dust ex-
tractor.

Noise/vibration information

Noise emission values determined according to EN
60335-2-69.
Typically the A-weighted sound pressure level of the dust ex-
tractor is 76 dB(A). Uncertainty K = 3 dB. The noise level
when working can exceed 80 dB(A).
Wear hearing protection
Total vibration values a
(triax vector sum) and uncertainty K
h
determined according to EN 60335-2-69: a
2
K = 1.5 m/s
.
Fitting
Pull the plug out of the socket before cleaning or per-
u
forming maintenance on the vacuum cleaner, making
tool adjustments, changing accessories or putting
away the vacuum cleaner. This safety measure prevents
the vacuum cleaner from being started accidentally.
Fitting the vacuuming accessories (see figure A)
The vacuum hose (15) is equipped with a clip system which
can be used to connect vacuuming accessories (dust extrac-
tion adapter (16), curved nozzle (17)).
Fitting the nozzles and tubes
– Push the curved nozzle (17) onto the vacuum hose (15)
until you hear both snap fasteners (27) on the vacuum
hose engage.
– Then attach the required extraction accessory (floor
nozzle, crevice nozzle, suction tube, etc.) firmly to the
curved nozzle (17).
– To remove the accessory, press the snap fasteners (27)
inwards and pull apart the components.
Fitting the dust extraction adapter (GAS 12-25 PL)
– Push the dust extraction adapter (16) onto the vacuum
hose (15) until you hear both snap fasteners (27) on the
vacuum hose engage.
– To remove the adapter, press the snap fasteners (27) in-
wards and pull apart the components.
Fitting the vacuum hose
Vacuuming function (see figure B1)
– Push the vacuum hose (15) into the hose connection
piece (3) and turn it as far as possible in the direction of
rotation .
Bosch Power Tools
Rated voltage
240 V
220–230 V
220 V
2
<2.5 m/s
,
h
Maximum power
1700 W
1000 W
1000 W
Note: The friction generated by the dust in the vacuum hose
and accessory during extraction causes an electrostatic
charge that the user may experience as static discharge (de-
pending on environmental factors and their physiological
state).
Bosch generally recommends using an anti-static vacuum
hose (accessory) to vacuum up fine dust and dry materials.
Blowing function (see figure B2)
The vacuum cleaner has a blowing function. Do not
u
blow exhaust air out into the open air. Only use the
blowing function with a clean hose. Dust can be hazard-
ous to health.
– Switch on the vacuum cleaner for at least five seconds
(GAS 12-25: On/off switch (1) to "on"; GAS 12-25 PL:
Mode selector switch (1) to the "vacuuming" symbol) to
clean the vacuum hose (15) of dust deposits.
– Turn the vacuum hose (15) as far as possible in the direc-
tion of rotation
and pull it out of the hose connection
piece (3).
– Push the vacuum hose (15) into the hose connection
piece (13) and turn it as far as possible in the direction of
rotation .
Removing/Inserting the Pre-filter
The pre-filter (22) prevents coarse dirt from getting through
and consequently extends the lifetime of the main filter. The
pre-filter must be removed from the container if you intend
to carry out wet vacuuming or to clean the main filter.
Removing the Pre-filter (see figure D1)
– Open the catches (9) and remove the top part of the va-
cuum cleaner (10) (see figure C).
– Remove the pre-filter (22) from the container (7).
Inserting the Pre-filter (see figure D2)
– Insert the pre-filter (22) in the container (7), making sure
that the arrows are pointing towards the hose connection
piece (3).
– Put the top part of the vacuum cleaner (10) on and close
the catches (9).
Removing/Inserting the Main Filter
The main filter (20) is a HEPA pleated filter with extremely
high filtration performance for cleaning exhaust air. You
need to remove the main filter from the container if you in-
tend to carry out wet vacuuming.
English | 11
Minimum power
100 W
100 W
100 W
1 609 92A 4S3 | (09.11.2018)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gas 12-25 plGas 12-25 professionalGas 12-25 pl professionalGas professional 12-25Gas professional 12-25 pl

Table des Matières