SAFETY POSITIONS FOLLOWING FAILURE OF
ELECTRICAL OR PNEUMATIC AUXILIARY POWER
Type of driving
up
down
up
down
up
down
Table 1: Safety settings following failure of electrical or pneumatic auxiliary power
5

MAINTENANCE

The Top Control ON/OFF is maintenance-free if operated according to the
directions given in these instructions.
Operating Instructions No. 801 872
Designation
Safety settings following failure
or auxillary power supply
electrical
single-acting
down
WW A
single-acting
up
WW B
double-acting
down / up
WW I
(depending on
connection of
control lines)
pneumatic
down
up
not defined