INSTALLATION – VENTED TO THE OUTSIDE
2
INSTALL MOUNTING BRACKETS
The vent hood must be secured to rear support framing
or a wall stud.
• With the template taped in place, use a punch to mark all
mounting screw locations.
• Drill 1/8" pilot holes at the 6 punched locations.
• Remove the template.
• Enlarge holes that did not enter studs to 3/8" and tap
anchors for wall fasteners into the holes.
– Drive screws into the fasteners to allow anchors to
expand against the wall material. Remove the screws
for final installation.
• Secure the mounting brackets to the wall studs with
wood screws provided.
3
INSTALL THE HOOD
Place the hood on the brackets and slide left to right to align
with rectangular slots at the top.
• Adjust the installation height by tightening or loosening
the screws "A" at the bottom of the brackets.
• Align the hood lower mounting holes with pilot holes in the
wall.
• Using two large washers (supplied), install wood screws or
wall-fastener screws, loosely, into lower mounting holes.
Do not tighten.
• Level the hood by tightening or loosening the screws "A"
located on the bottom mounting brackets.
• Tighten the lower mounting screws.
• Tighten screws "B" located at the top of the mounting
bracket against the hood to adjust position. Do not
overtighten screws.
Installation Instructions
10
Screws "B"
Screws "A"
NOTE: Screws "A" and "B" are preassembled onto the
brackets. Do not remove these screws.
Screws "B" to adjust
hood against wall
Lower mounting
screws
Level and height
adjustment
screws "A"