INSTALL DUCT COVERS
1. For ducted and recirculation installation:
Remove protective film from duct covers. Place
the upper duct cover so that it slides down inside
of the lower duct cover.
NOTE: For recirculation, the upper duct cover
must be installed with the exhaust vents on the
top towards the ceiling.
Depending on the amount of overlap between
the top and bottom duct covers, the top may be
reversed to hide vent holes. Refer to Installation
Height Table for possible heights.
Place the set of duct covers by sitting them
down to fit securely on top of the hood. Finish
attaching the lower duct cover to the body of the
hood with two machine screws (J) that screw
from up underneath the hood.
2. Install the upper duct cover by carefully raising
it up to avoid scratching until it reaches the
ceiling. Push the duct cover flush against the
wall, then use two machine screws (J) to mount
the upper duct to the duct mounting bracket.
3. If recirculating, install the charcoal filters. Then
reinstall the grease filters to the hood, see the
Filters section.
4. Turn the power supply on. Turn on the blower
and light. If the range hood does not operate,
check that the circuit breaker is not tripped or the
house fuse blown. If the unit still does not operate,
disconnect the power supply and check that the
wiring connections have been made properly.