3.2) Operation
– Operate push button (GREEN) on the remote hand controller (10) to activate the motor and pump
oil to the hydraulic head.
– The pump will stop automatically when the nominal operating pressure is achieved, and oil pres-
sure will be maintained, conserving battery capacity. If the push button is released before the
nominal operating pressure is reached, the pump will stop and will maintain the oil pressure at
the achieved level. To complete the operating cycle, press and hold the push button.
– By pressing the pressure release button (RED) the ram of the hydraulic head connected to the
pump will retract. To interrupt the "RETURN OIL" stage, release the button:
the ram of the hydraulic head will stop in the position reached.
NOTE: If required, by pressing hard on the mechanical pressure
release button (05), positioned on the front of the pump, the oil
will return to the reservoir whatever the status of the battery
or external power supply.
D
O NOT BUILD UP PRESSURE IF THE PUMP IS NOT CON
NECTED TO THE FLEXIBLE HOSE AND THE HEAD
DAMAGE THE PUMP QUICK COUPLER
.
OIL SEEPAGE

3.3) Battery status

Inserting the battery into the pump or releasing the operating push button, automatically displays
the residual power level for 5 seconds (06).
The number of led's illuminated indicates the residual power level:
,
THIS MAY
,
(09)
THUS ORIGINATING
05
-
06
10 leds illuminated: fully charged
5 leds illuminated: 50 % capacity
1 led illuminated: minimum charge