TROUBLESHOOTING

Problem
Blower doesn't
work.
Tool operates
intermittently.
The air velocity
decreases
noticeably.
Cause
1. The battery pack is not
attached to the blower.
2. No electrical contact
between the blower and
the battery pack.
3. The battery pack is
depleted.
4. The battery pack or the
blower is too hot.
5. The on/off dial
malfunction.
6. The motor malfunction.
1. The on/off dial is
defective.
2. The internal wiring is
defective.
1. Excessive wear of the fan. 1. Have the tool serviced by an
2. The air inlet is blocked by
debris.
Remedy
1. Attach the battery pack to the blower.
2. Remove the battery pack, check the
contacts and reinstall the battery pack.
3. Charge the battery pack.
4. Turn off the blower and remove the
battery pack from the blower. Allow the
battery pack and/or the blower to cool
down.
5. Have the tool serviced by an
Authorized SKIL Service Center or
Service Station.
6. Have the tool serviced by an
Authorized SKIL Service Center or
Service Station.
1. Have the tool serviced by an
Authorized SKIL Service Center or
Service Station.
2. Have the tool serviced by an
Authorized SKIL Service Center or
Service Station.
Authorized SKIL Service Center or
Service Station.
2. Remove the battery pack and clear the
debris.