Leak Testing Instructions
This must be done before initial use, annually, and whenever any gas components
are replaced or serviced. Do not smoke while performing this test, and remove all
sources of ignition. See Leak Testing Diagram for areas to check. Never conduct a
leak test using fire or flame. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Testing a Gas Leak
Ensure all control knobs are in the off position.
STOP
Turn on the fuel supply.
Brush or spray a half-and-half solution of liquid soap and water onto all joints and connections of
the regulator, hose, manifolds and valves.
Bubbles will indicate a gas leak. IMMEDIATELY turn off the gas supply.
See next page for "Fixing a Gas Leak".
Propane Gas
Leak Testing Diagram
WARNING
For Propane gas turn the cylinder valve knob counter clockwise one full
rotation.
50% WATER
Spray
50% LIQUID
SOAP
or
Brush