Ensure a tight and secure fit.
Make sure that no metallic compo-
nents are in the immediate vicinity
of the sensor or approach the sen-
sor during operation (especially no
metal rings around the sensor etc.)!
This might impair the function of
the sensor.
Fixing elements such as screws,
clamps and similar small metal parts
(< 20 x 30mm) have no effect on
the sensor.
For safe functioning the adapter (3)
must consist of plastic.
3 Electrical connection
The unit must be connected by a qualified electrician. The national and
international regulations for the installation of electrical equipment
must be observed.
Disconnect power before connecting the unit as follows:
A = metallic objects
x = min. 10mm
y = min. 46,5mm
5: OUT1 = seat
2: OUT2 = close
4: OUT3 = open
21