9 Product description
The digital multimeter (multimeter) displays measurements on a digital display (dis-
play). The multimeter features a digital 6000-count display (count = smallest display
value). The multimeter monitors the correct socket assignment. The multimeter
beeps and displays a warning when the sockets are not assigned correctly. This
increases the operational safety of the multimeter for the user.
The multimeter switches off automatically after a preset time if no buttons are
pressed. This protects the batteries and extends the battery life. The automatic shut-
off feature can be preset and disabled manually.
The multimeter can be used to take measurements up to CAT III 1000 V/CAT IV
600 V. It is suitable for use in hobby and professional applications.
The multimeter can be placed on a level surface using the fold-out stand for better
readability.
The battery and fuse compartment can only be opened when all test leads have
been disconnected from the multimeter. When the battery and fuse compartment
are open, the test leads cannot be inserted into the measurement sockets. This is a
built-in safety feature to protect the user.
Control dial (E)
Individual measurement modes are selected using the control dial. Automatic range
selection ("Autorange") is enabled in most measurement modes. The measurement
range will be selected automatically. The current measurement ranges must be set
manually. Always start current measurements with the largest measurement range,
and then switch to a smaller range if necessary.
The control dial features an indicator light that shows the setting position. Use the
"SELECT" button to switch to a sub-mode when the measurement mode has more
than one function (e.g. to switch from resistance measurement to continuity test or
from AC to DC current). The function is toggled with each press.
To switch the multimeter off, move the control dial to the "OFF" position. Always turn
the multimeter off when it is not in use.