5.
a. Fit the rubber seal. Make sure the seal
reach the bottom of the track properly.
(picture 5a)
b. Fit the end of the rubber seal with a screw
before the rest of the seal is mounted.
(picture 5b)
c. Rail lengths (picture 5c)
5 - 27,5 m: 2 screws for each rubber seal.
30 - 50 m: 3 screws for each rubber seal.
0 - 100 m: 4 screws for each rubber seal.
.
20/1500 (picture ):
The schock absorber on the driving direction side.
7.
a, b Template for locating holes (picture 7a, 7b)
c. End stops (picture 7c):
•
To be fitted in both rail ends when the rail is
used for stationary vehicles.
•
To be fitted in the start rail end only, when the
rail is used for vehicles in motion.
8.
a. Trolley stop (picture 8a, 8b):
•
Only for vehicles in motion.
•
Must only be fitted in the rail end where the
disconnection takes place.
SYSTEM 920
Fans
Fans are not included in the basic package. For the
best results, one fan per extraction unit is recom-
mended. It is also possible to connect several units
to a central fan.
To get underpressure in the ducting system and avoid
exhaust leakage, the fan should be positioned as near
the duct outlet from the room as possible.
Alternative connection for fan.
(picture 11a, 11b, 11c))
Automatic disconnection (picture 12)
Extraction units delivered with automatic disconnec-
tion have a factory adjusted wire connected to trolley,
safety coupling and nozzle.
The disconnection trigger must be fitted to the rail
according to the figures. The dimension X must be
minimum 1,0 m, but adjusting to required position
for disconnection must be made at the place of
installation.
GB
15