English
GENERAL MAINTENANCE GUIDE
To ensure the maximum life of the MultiCyclone DUO, please follow the procedures
below:
1. Clean the filter cartridge element regularly according to the instructions set under
"MultiCyclone Filter Cartridge Element"
2. Maintain a correct chemical balance of your pool/spa water. The chemical balance
of water is a relationship between its pH, total alkalinity, calcium hardness and
water temperature. The water must be maintained at all times to the following:
PH LEVEL
TOTAL ALKALINITY
CALCIUM HARDNESS
Also, within these tolerances be balanced to the Langelier Saturation Index within a
range of -0.2 to +0.2.
Note: Testing kits are available to test the water yourself or alternately bring a sample
of the water to a professional pool and spa shop.
3. Mains water and rural water supplies need to be monitored. Saturation (life) in
mains water or bore (rural) will vary depending on water quality.
4. To prevent damage to the pump and filter and for proper operation of the system,
clean pump strainer and skimmer baskets regularly.
5. Replace the pressure gauge if faulty readings are observed.
WINTERIZING
Proper winterizing procedures should always be taken in order to protect your filter in
cold climates (temperatures below freezing point).
1. Switch off the Pump/Close the inlet valve.
2. Open the air release valve and open the purge valve to allow water to flow out of
the MultiCyclone DUO.
3. Remove any drain plugs from the pump.
4. Drain water from the pipe work.
: BETWEEN 7.2 & 7.8.
: BETWEEN 80 & 150ppm.
: BETWEEN 150 & 300ppm.