Screw the supplied half barrel unions and tails onto the inlet and outlet before gluing
the UPVC piping onto the filter.
!
Note: Do not use liquid sealant or thread tape on the thread of the inlet or outlet
threads of the MultiCyclone or connecting barrel union threads.
Use only recommended glue for connection pipe and fittings
Cut and fit the pipe and fittings onto the MultiCyclone DUO and the pump. Refer to
Pump Installation Manual for correct pump plumbing procedures.
It is best practice to fit all the cut pipe and fittings onto the filtration system before
gluing; this will ensure that the system has been aligned correctly.
Glue the pipe and fittings onto the pump, filter and pool return lines and allow the
glue to set for 24 hours before commissioning the system.
Plumbing Connection
1. Connect the pipe extending from the pump outlet to the inlet of the MultiCyclone
DUO.
2. Connect from the pipe extending from the outlet of the MultiCyclone DUO to the
next component in line with the filtration system or water return line.
3. Glue all plumbing to barrel union fittings in accordance with glue (solvent)
manufactures specifications and allow 24 hours to set. Ensure glue (solvent) is not
excessively applied to fittings as this could run onto "o"-rings and create sealing
problems.
Note: Waterco recommends that a shut off valve be installed after the MultiCyclone
DUO on the pool return line to assist with flushing out the collected debris. Please
refer to "Insufficient Water Pressure".
4. Turn on pool pump. Be sure to check that there are no leaks from the connectors.
If required, tighten by hand.