FILTER CARTRIDGE MAINTENANCE
To ensure maximum life from your MultiCyclone DUO filter cartridge you need to
maintain the filter cartridge regularly.
When the filter is first started and has been purged of air, note the pressure on
the pressure gauge. This is what is known as the filter operating pressure and it is
important that you be aware of this figure.
All filtration systems will operate at different pressures depending on the pool
hydraulics.
You will need to clean the filter cartridge once the pressure gauge has reached 50kPa
(7.2psi) above the operating pressure.
Example : Filter operates normally at 60kPa (8.2psi) needs to be cleaned at 110kPa
(16psi).
Cartridge Element Cleaning
Prior to removing the MultiCyclone DUO cartridge filter's lid, you will need to release
the pressure from the filter cartridge housing. With the pump off, loosen the air
release valve on top of the MultiCyclone DUO filter lid to release pressure from the
filter housing.
1. The MultiCyclone DUO filter features a innovative locking mechanism designed for
unparalleled convenience. With a simple clockwise turn of the lock ring, you can
securely lock the filter in place.
Note: Ensure the locking ring's locking plunger passes the filter tank's retaining
lugs and is properly installed and tightened to prevent water leaks.
When it's time for cartridge replacement, simply press and hold the lock plunger
while simultaneously turning the lock ring anti-clockwise. The innovative lifting lug
integrated into the lid effortlessly lifts the lid together with the lock ring, granting
you quick and easy access to the filter cartridge.
2. Remove the filter cartridge element from the filter housing.
3. Using a garden type hose clean the surface of the pleated element. Make sure to
clean between the cartridge element pleats.
4. Place the filter cartridge element back into the filter housing ensuring that it is
seated correctly.
5. Ensure the lid "o"-ring is clean of any debris and is correctly seated into filter body
"o"-ring groove prior to lid being refitted.