1
Safety Guidelines
1.
Follow the installation instructions
2.
Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger
3.
Note that the appliance is exclusively for use in the
applications detailed in these installation instructions
(see 2 Technical Data). Any other use will not be
considered to comply with requirements and would
invalidate the warranty
4.
Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried
out by authorized persons.
5.
Immediately rectify any malfunctions which may
influence safety
2
Technical Data
Media
Medium:
Connections/Sizes
Connection sizes:
Nominal sizes:
Pressure values
Max. inlet pressure:
Outlet pressure:
Preset outlet pressure:
Min. pressure drop:
Operating temperatures
Max. operating temperature
medium accord. to EN 1567:
Max. operating temperature
medium (10 bar):
3
Options
For Options visit resideo.com
4
Assembly
4.1 Installation Guidelines
•
Horizontal and vertical installation position possible
– In vertical installation position spring bonnet with
adjustment knob facing upwards
•
Install shut-off valves
•
The installation location should be protected against
frost and be easily accessible
– Pressure gauge can be read off easily
– Simplified maintenance and cleaning
•
To guarantee perfect functioning, a filter must be
inserted ahead of the pressure reducing valve
d05fs-ef-ii-mu1h1052ge23r0125.pdf 2
GB
•
•
4.2 Assembly instructions
1.
2.
3.
5
Drinking water
5.1 Setting outlet pressure
1
/
" - 1"
2
1.
DN15 - DN25
2.
25 bar
3.
1.5 - 5.5 bar
4.
5.
3 bar
1 bar
6.
30 °C
7.
70 °C
8.
9.
10.
6
In accordance with EN 806-5, the following measures must
be taken:
6.1 Inspection
1.
2.
2
Provide a straight section of pipework of at least five
times the nominal valve size after the pressure
reducing valve (in accordance with EN 806-2)
Requires regular maintenance in accordance with
EN 806-5
CAUTION!
When using soldering connections, do not solder
the connections together with the pressure
reducing valve! High temperature will irreparably
damage important internal working components!
Thoroughly flush pipework
Install pressure reducing valve
• Note flow direction
• Install without tension or bending stresses
Set outlet pressure
Start-up
Set outlet pressure min. 1 bar under inlet pressure.
Close shut-off valve on inlet
Release pressure on outlet side (e.g. through water
tap)
Fit pressure gauge (optional)
Close shut-off valve on outlet
Loosen slotted screw
• Do not remove slotted screw
Slacken tension in compression spring
• Turn adjustment handle counter clockwise (-) until
it does not move any more
Slowly open shut-off valve on inlet
Turn adjuster knob until the manometer shows the
desired value
Retighten slotted screw
Slowly open shut-off valve on outlet
Maintenance
In order to comply with EN 806-5, water fixtures must
be inspected and serviced on an annual basis.
As all maintenance work must be carried out by an
installation company, it is recommended that a
servicing contract should be taken out.
Close shut-off valve on outlet
Check outlet pressure using a pressure meter when
there is zero through-flow
MU1H-1052GE23 R0125
06.02.2025 09:04:07