Possible misuse
▶ Do not use the power tool to cut bricks, concrete, cellular concrete, natural stone or tiles.
▶ Do not use the product to cut pipes that still contain liquids.
▶ Do not saw into unknown materials.
3.4
Liion battery status indicator
The charge state of the Li-ion battery and malfunctions of the power tool are indicated by the indicator of
the Liion battery. The charge status of the Liion battery is indicated after one of the two battery release
buttons is short-pressed.
Status
4 LEDs light up.
3 LEDs light up.
2 LEDs light up.
1 LED lights up.
1 LED flashes.
1 LED blinks, the power tool is not ready for use.
4 LEDs blink, the power tool is not ready for use.
Battery charge state cannot be indicated while the control switch is pressed and for 5 seconds after
the control switch has been released. If the LEDs of the charge state indicator flash, follow the
instructions in the 'Troubleshooting' section.
3.5
Items supplied
Reciprocating saw, operating instructions.
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group | USA: www.hilti.com
4
Technical data
4.1
Reciprocating saw
Rated voltage
Weight in accordance with EPTA procedure 01
Stroke rate
Stroke length
Keyless chuck for standard accessory tools
4.2
Battery
Battery operating voltage
Ambient temperature
Storage temperature
4.3
Noise information and vibration values in accordance with EN 60745
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure. The data given represents the main applications of the power tool.
However, if the power tool is used for different applications, with different accessory tools, or is poorly
maintained, the data can vary. This can significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the
2200411
*2200411*
Printed: 23.03.2018 | Doc-Nr: PUB / 5408534 / 000 / 01
Meaning
•
Charge state: 75 % to 100 %
•
Charge state: 50 % to 75 %
•
Charge state: 25 % to 50 %
•
Charge state: 10 % to 25 %
•
Charge state: < 10 %
•
The battery has overheated or is completely
discharged.
•
The power tool is overloaded or has overheated.
SR 4-A22
21.6 V
3.8 kg
0 /min ... 3,000 /min
28 mm
1/2 in
21.6 V
−17 ℃ ... 60 ℃
−20 ℃ ... 40 ℃
English