Your pump has been carefully packaged at the
factory to prevent damage during shipping.
However, occasional damage may occur due
to rough handling. Carefully inspect your
pump for damages that could cause failures.
Report any damage to your carrier or your
point of purchase.
Please read these instructions carefully. Failure to comply to instructions
and designed operation of this system, may void the warranty.
READ THIS DOCUMENT IN TOTALITY PRIOR
TO STARTING THE INSTALLATION.
PRIMING PROCESS
Follow all these step by step instructions to install your pump. Use
teflon tape on all threads. (1) Fill the suction line with water and connect
it to the suction inlet. (2) Remove the priming plug and fill the pump
body with water. (3) Screw the plug to the priming inlet. (4) Turn the
power on. The pump should deliver water to the plumbing line within
30 seconds. If not, unplug the pump and repeat the process at step 2.
Discharge
connection
1
Suction
connection
Tel. : 514.337.4415
Fax : 514.337.4029
info@burcam.com
www.burcam.com
INSTALLATION
INSTRUCTIONS
JET PUMP
506522SS
FACTORY SET VOLTAGE
115 V TO CHANGE THE
A) Ensure the power to
the pump is disconnected.
B) Open motor junction
C) Please select the up knob
position for 115V or down
knob position for 230V.
E) Close motor junction box.
© 2024 BURCAM Printed in Canada 510164
MODEL
VOLTAGE :
Before changing the
voltage connection:
box cover.
D) Connect to
appropriate voltage.