Télécharger Imprimer la page

Publicité

Liens rapides

2190 Dagenais Blvd.West
Laval (Quebec)
Canada
H7L 5X9
see us at
Your pump has been carefully packaged at the
factory to prevent damage during shipping.
However, occasional damage may occur due
to rough handling. Carefully inspect your
pump for damages that could cause failures.
Report any damage to your carrier or your
point of purchase.
Please read these instructions carefully. Failure to comply to instructions
and designed operation of this system, may void the warranty.
READ THIS DOCUMENT IN TOTALITY PRIOR
TO STARTING THE INSTALLATION.
PRIMING PROCESS
Follow all these step by step instructions to install your pump. Use
teflon tape on all threads. (1) Fill the suction line with water and connect
it to the suction inlet. (2) Remove the priming plug and fill the pump
body with water. (3) Screw the plug to the priming inlet. (4) Turn the
power on. The pump should deliver water to the plumbing line within
30 seconds. If not, unplug the pump and repeat the process at step 2.
Discharge
connection
1
Suction
connection
Tel. : 514.337.4415
Fax : 514.337.4029
info@burcam.com
www.burcam.com
INSTALLATION
INSTRUCTIONS
JET PUMP
506522SS
FACTORY SET VOLTAGE
115 V TO CHANGE THE
A) Ensure the power to
the pump is disconnected.
B) Open motor junction
C) Please select the up knob
position for 115V or down
knob position for 230V.
E) Close motor junction box.
© 2024 BURCAM Printed in Canada 510164
MODEL
VOLTAGE :
Before changing the
voltage connection:
box cover.
D) Connect to
appropriate voltage.
4

Publicité

loading

Sommaire des Matières pour Burcam 506522SS

  • Page 1 The pump should deliver water to the plumbing line within appropriate voltage. 30 seconds. If not, unplug the pump and repeat the process at step 2. E) Close motor junction box. Discharge connection Suction connection © 2024 BURCAM Printed in Canada 510164...
  • Page 2 SAFETY INSTRUCTIONS This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures : Check with your local electrical and plumbing codes to ensure you comply with the regulations.
  • Page 3 APPLICATION : FEATURES :  This pump is designed for shallow well  304 stainless steel pump body, easy installation for water level up to 25 feet. to prime.       CAPACITY AT 20 PSI :  Totally enclosed, fan-cooled motor. ...
  • Page 4 SHALLOW WELL APPLICATION SEE DIAGRAM ON PAGE 7 Cut the desired length of poly pipe to run from the top of the well to the STEP 2 pumping level. Smooth the pipe cuttings with your round file. (Check that no cut-out parts are left inside of pipe.
  • Page 5 TANK INSTALLATION SEE DIAGRAM ON PAGE 8 Packaged systems have the pump mounted directly to the tank. The pump to STEP 9 tank plumbing fittings are pre-assembled at the factory. You only have to connect the discharge line of your system to your home’s plumbing distribution line. When using a separate tank from your pump, we recommend that you install a captive air tank as shown in our typical installation diagram, that is air injected into the tank at the factory.
  • Page 6 ELECTRICAL INSTALLATION VOLTAGE SELECTION SWITCH 1. POWER off. 2. Please SELECT the up knob position for 115 V or down knob position for 230 V. Electrical line from home distribution panel. 3. CONNECT to appropriate power source. BLACK GREEN GROUND To motor lead We recommend that a licensed electrician be employed to do the proper wiring to the pressure switch, and to permanently ground the motor in accordance to the electrical...
  • Page 7 SHALLOW WELL APPLICATION STEP 5 Install your pump and thread an adaptor into inlet. STEP 6 Cut poly pipe and connect both ends. STEP 3 Insert well seal elbow through the seal and attach to pipe. STEP 4 Install well seal and piping into well casing.
  • Page 8 TANK INSTALLATION Snifter valve to adjust air pressure. Pressure switch 1/4" connection if not included with the pump. Relief valve Pressure gauge for pumps 1/4" connection. with more than 75 PSI of capacity 1/2" connection. Drain valve 1/2" connection. 1" MNPT or 3/4" FNPT connection.
  • Page 9 Pressure switch 510005 Venturi / Diffuser 510017 Tube 510006 Impeller 510016 Tube elbow 510008.1 Mechanical seal 510002 Pressure gauge 510009 Seal plate ‘‘O’’ ring 510163 Complete motor Repair parts may be ordered your authorized point of sale of from BURCAM PUMPS...
  • Page 10 TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Switch is off position Turn switch to on position Motor does Blown fuse...
  • Page 11 E) Brancher à la source distribution à l’intérieur de 30 secondes. Sinon, débrancher la pompe de voltage appropriée à et répéter le processus à l’étape 2. l’interrupteur à pression. Branchement de la décharge Branchement de la succion © 2024 BURCAM Imprimé au Canada 510164...
  • Page 12 CONSEILS DE SÉCURITÉ La pompe que vous venez d’acquérir est un produit fabriqué avec les meilleurs matériaux et par une main-d’oeuvre spécialisée. Veuillez suivre les instructions d’utilisation et prendre les précautions nécessaires pour votre sécurité : Consultez les normes de plomberie et d’électricité se rapportant à votre région, pour vous assurer des règles à...
  • Page 13 APPLICATION : CARACTÉRISTIQUES :  Cette pompe est conçue pour un puits de  Boîtier en acier inoxydable 304, facile surface dont le niveau d’eau est inférieur à amorcer. à 25 pieds.  Moteur complètement fermé, refroidi par un ventilateur. Roulement à billes aux CAPACITÉ...
  • Page 14 APPLICATION POUR PUITS DE SURFACE VOIR LE DIAGRAMME À LA PAGE 7 Couper la longueur désirée de tuyau du haut du puits au niveau de ÉTAPE 2 pompage. Adoucir les bouts du tuyau avec la lime ronde (Assurez-vous qu’aucun rebut de coupe ne reste à l’intérieur du tuyau. Ceci pourrait bloquer l’injecteur ou l’impulseur de votre pompe).
  • Page 15 INSTALLATION DU RÉSERVOIR VOIR LE DIAGRAMME À LA PAGE 8 Pour les ensembles de système d’eau dont la pompe et le réservoir ont déjà été ÉTAPE 9 assemblés en usine, le seul raccord à effectuer est de brancher la décharge de la pompe au réseau de plomberie de la maison.
  • Page 16 INSTALLATION ÉLECTRIQUE SÉLECTEUR DE VOLTAGE 1. COUPER l’alimentation électrique. 2. Veuillez GLISSER vers le bas le sélecteur de voltage pour obtenir du 115V, ou vers le haut pour le 230 V. Alimentation électrique provenant du panneau de distribution. 3. BRANCHER à la source appropriée. NOIR ROUGE VERT...
  • Page 17 APPLICATION POUR PUITS DE SURFACE ÉTAPE 5 Installer votre pompe et visser un adaptateur dans la succion. ÉTAPE 6 Couper le tuyau et raccorder les extrémités. ÉTAPE 3 Insérer le coude dans le sceau d’étanchéité et le raccorder au tuyau. ÉTAPE 4 Installer le sceau d’étanchéité...
  • Page 18 INSTALLATION DU RÉSERVOIR Reniflard d’ajustement de la pression d’air. Interrupteur à pression, raccord 1/4’’, sinon inclus avec la pompe. Valve de sécurité pour Manomètre de les pompes pression, raccord 1/4’’. développant plus de 75 lb/po, raccord 1/2’’. Valve de drain Raccord 3/4"...
  • Page 19 510017 Tube 510006 Impulseur 510016 Coude du tube 510008.1 Sceau mécanique 510002 Manomètre 510009 Rondelle de la plaque 510163 Moteur complet du sceau Les pièces de rechange peuvent être commandées de votre point de vente autorisé ou de POMPES BURCAM...
  • Page 20 GUIDE DE RÉSOLUTION DES PROBLÈMES LORS D’AJUSTEMENT SUR DES APPAREILS ÉLECTRIQUES, TOUJOURS S’ASSURER QUE LE COURANT EST DÉBRANCHÉ. NE PAS SEULEMENT ENLEVER LE FUSIBLE OU METTRE LE DISJONCTEUR HORS TENSION. IL FAUT DÉBRANCHER LE CÂBLE D’ALIMENTATION DE LA PRISE. TROUBLE PROBABLE CAUSE ACTION Commutateur hors circuit...