Appareil de réfrigération sous plan

Publicité

Installation Instructions
Integrated Panel
Dimensions
NOTE
• Due to differences in surrounding cabinetry, the panel may not perfectly align with
the door. The procedure below is designed to provide a finished integrated panel that
seamlessly integrates with surrounding cabinetry.
• Panel Preparation: a full integrated door panel completely covers the door frame so it
appears built-in.
• The door panel must not weigh more than 22 lbs (10 kg). It is important to ensure
that all holes are drilled to the correct depth in order to avoid splits in the wood when
hardware is installed.
1. Cut the panels to the dimensions listed in the diagram below.
2. Optional: Stain or finish the panel to your desired stain or color. Be sure to closely
follow the instructions provided by the manufacturer.
3. Optional: Install handles and hardware.
6 3/8" (16.1 cm)
4 5/16" (10.9 cm)
3/4" (1.9 cm)
NOTE
• The appliance will need up to (870 mm) below the underside of the counter to leave
room for leveling adjustments.
• When applying an integrated frame to a unit,ensure that both sides are finished in
order to prevent warping. In some frame installations, the panel may be visible through
the glass while the door is open.
32
English
Dacor_BRW5500D_IM_EN.indd 32
Door base
23 11/16" (60.1 cm)
8 11/16" (22.1 cm)
6 3/8" (16.1 cm)
4 5/16" (10.9 cm)
2 3/16" (5.5 cm)
Door panel
23 3/4" (60.3 cm)
8 11/16" (22.1 cm)
3/4" (1.9 cm)
2 3/8" (6.0 cm)
3/4" (1.9 cm)