Plug the float switch, pump and charger into the control box.
STEP 11
The connections are marked on the control box.
Test pump operation by filling the sump with water while the main pump is
STEP 12
unplugged. If the pump operates properly, plug the charger into the GFCI
protected outlet to begin charging the battery.
Protect electrical cord from sharp objects, hot surfaces, oil and chemicals.
STEP 13
Avoid kinking the cord and replace damaged components immediatly.
The control box contains a multi-colored indicator light. When AC power is present, the
light will indicate the charging state, and not reflect actual battery voltage, particularly
with a defective battery.
In order for the indicator light to provide an accurate reading, steps 1 throught 3 must
be followed.
1- Unplug main AC pump and the charger. A power-off alert tone will sound for 30 second.
2- Lift and release the float switch to activated.
3- When the pump stops, read the test light :
GREEN : Indicates battery is charged.
YELLOW : Voltage is low, indicating battery is partially charged.
RED : Battery is completely discharged or defective.
4- Plug in charger and main AC pump. When AC power is out, and when the pump has
been running, the light will indicate battery status.
REF.
PARTS
DESCRIPTION
1
310660
2
310661
3
310672
4
310667
5
310673
6
310670
7
310666
8
310659
9
  3 10676
10
310677
11
310663
12
310662
13
52259
14
52258
16
310665
17
310664
18
310668
19
310671
FOR INFORMATION | TEL : 514.337.4415 | FAX : 514.337.4029
REPAIR PARTS
Upper box cover
Lower box base
Alternative handles (2)
Screws (4)
PVC ties (4)
Black belt
Float
Pump
Impeller & lock washer
Pump 'O' ring
Volute
Suction screen
Reducer 1'' to 1 1/4''
90°elbow
AC adaptor
Control box
Big head screws (4)
Battery cable clamps
5

Publicité

loading