Télécharger Imprimer la page

Burcam 400405T Instructions D'installation page 3

Masquer les pouces Voir aussi pour 400405T:

Publicité

APPLICATIONS :
 This domestic submersible sewage
pumps is designed and suitable
for raw sewage applications where
the total head requirements do not
exceed 25, 35 or 40 feet, including
pipe friction losses.
CAPACITY :
     
400405T
5'
4200 US GPH
10'
3300 US GPH
15'
2400 US GPH
20'
1500 US GPH
25'
600 US GPH
30'
35'
40'
We recommend that you install your pump and basin in a clean location
STEP 1
where there is adequate room for servicing at a later date. Protection from
freezing temperatures and good ventilation should be considered as well,
to provide the pump an environment for long life.
Assuming that you have a sump pit located in your basement floor. Your
sump pit should be constructed from concrete, brick, tile or more recently
a sump basin made from plastic and/or fiberglass. The minimum size of
your sump pit must be 18'' in diameter and no less than 25'' deep. When
pit is ready, proceed to next step.
Friction losses in the discharge pipe must be taken into consideration
when many elbows and fittings are installed in the discharge line. Each
elbows and fittings must be considerated as 1 feet of head.
Never run the pump dry. Damage to the seal may occur.
THE RUN OF THE PIPE FROM THE CHECK VALVE MUST NEVER BE
SLOPING DOWNWARD EXCEPT AT THE FINAL CONNECTION TO THE
EXISTING WASTE OR DRAIN LINE.
For a new installation, install your sewage basin in the excavation you
STEP 2
have provided in the basement floor of your home. Connect the necessary
piping from your shower trap, toilet, etc., to the inlet of your sewage basin,
with the proper pipe and fittings (see diagram).
Cut a lenght of 40'' to 42'' of 2'' ABS/DWV pipe. Cement the 2'' ABS/DWV
STEP 3
male adaptor to 2'' slip to end this pipe.
FOR INFORMATION | TEL : 514.337.4415 | FAX : 514.337.4029
Friction loss in pipe
not included.
400406T
400409T
5700 US GPH
10200 US GPH
4800 US GPH
9000 US GPH
3900 US GPH
7800 US GPH
3000 US GPH
6600 US GPH
2100 US GPH
5400 US GPH
1100 US GPH
4200 US GPH
    4 00 US GPH
3000 US GPH
1800 US GPH
INSTALLATION STEPS
see typical installation diagram in page 4
FEATURES :
 Vortex designed impeller made from
cast iron.
 Rugged cast iron pump body.
 Stainless steel motor body.
 Stainless steel mechanical rotary
type motor seal.
 2'' NPT pump discharge.
 Thermal and overload protection.
 3/4 HP, 115VAC, 60Hz, 9A,
oil filled base.
 1 HP, 230VAC, 60Hz, 8A,
oil filled base.
 2 HP, 230VAC, 60Hz, 15A,
oil filled base.
3
3

Publicité

loading

Ce manuel est également adapté pour:

400406t400409t