APPLICATION :
 Designed for a permanent installation for
homes and cottages application.
CAPACITY :
HEAD
US GPH HEAD LPH
12.0m
120
9.0m
1100
6.0m
2000
3.0m
2800
1.5m
3100
The following are minimum requirements in order to protect your residence from flooding. It
is a small investment but it is your personal responsibility to protect your home, family and
valuables. Failure to comply with the following requirements will also void your warranty :
- Two (2) pumps have to be installed in the sewage pit. The first pump as a primary pump
and the second pump as the backup unit.
- An alarm system model 450455 has to be installed to advise you of any malfunctions.
Pump selection, proper and adequate installation are a must to comply with local by-laws and
need to be adhered to.
We recommend that you install your pump and basin in a clean location
STEP 1
where there is adequate room for servicing at a later date. Protection
from freezing temperatures and good ventilation should be considered as
well, to provide the pump an environment for long life. Assuming that you
have a sump pit located in your basement floor. Your sump pit should be
constructed from concrete, brick, tile or more recently a sump basin made
from plastic and/or fiberglass. The minimum size of your sump pit must
be 18'' in diameter and no less than 25'' deep. Ehen pit is ready, proceed
to next step. Friction lossees in the discharge pipe must be taken into
consideration when many elbows and fittings are installed in the discharge
line. Each elbows and fittings must be considered as 1 feet of head. Never
run the pump dry. Damage to the seal may occur. THE RUN OF THE PIPE
FROM THE CHECK VALVE MUST NEVER BE SLOPING DOWNWARD
EXCEPT AT THE FINAL CONNECTION TO THE EXISTING WASTE OR
DRAIN LINE.
For a new installation, install your sewage basin in the excavation you
STEP 2
have provided in the basement floor of your home. Connect the necessary
piping from your shower trap, toilet, etc., to the inlet of your sewage basin,
with the proper pipe and fittings (see diagram).
Cut a lenght of 40'' to 42'' of 2'' ABS/DWV pipe. Cement the 2'' ABS/DWV
STEP 3
male adaptor to 2'' slip to end this pipe.
40'
450
30'
4165
20'
7570
Friction loss in pipe
10'
10600
5'
11735
IMPORTANTE NOTICE
INSTALLATION STEPS
See typical installation diagram in page 4
FEATURES :
 1 HP.
 115V AC.
 60Hz.
 12A (20A breaker required).